The sample was randomly divided

The sample was randomly divided Crizotinib into two groups: the Stretching Group (n=15), which performed 6.5 minutes of stretching and the Control Group (n=15), which remained seated for the same period of time. Procedures The study was performed in accordance with the ethical standards (Harriss and Atkinson, 2009). Moreover, the local Ethics Committee, in accordance with the Helsinki Declaration, approved all procedures prior to the start of this investigation. All volunteers completed a medical screening questionnaire and provided written informed consent prior to participation. The Stretching Group performed a bout of stretching focusing on their dominant quadriceps muscle, which included ten passive stretches lasting 30 s each with a 10 s rest between stretches (Torres et al., 2007).

All passive stretching was observed by the same examiner, who limited the stretch until he felt reasonable resistance or the subject reported discomfort (Johansson et al., 1999). The subject was in a standing position with one knee resting on a chair. The dominant leg was kept relaxed; the examiner passively stretched the quadriceps, flexing maximally the subject��s knee and extending the hip to a neutral position. If maximal knee flexion did not produce the sensation of a stretch or resistance against the movement, hip extension would be added in order to increase the stretch. No intervention was made in the Control Group, which remained seated while the stretching program was conducted. The dependent variables included knee JPS, TTDPM, and the sense of force, which were recorded in random order before, immediately afterward, and one hour after the stretching program.

The protocol for the JPS assessment involved passive positioning and active repositioning (passive-active test) of the dominant leg (Zhou et al., 2008). JPS measurements were performed with an isokinetic dynamometer (Biodex Medical Systems, Inc., Shirley, NY, USA) (Callaghan et al., 2002). The Biodex System 3 isokinetic dynamometer is a mechanically reliable instrument for the measurement of an angular position, isometric torque, and slow to moderately high velocities, with high intra-class correlation coefficients (ICC 2,K = 0.99 for each variable) (Drouin et al., 2004). Test instructions were given to the participants prior to their initiation and they were allowed to familiarise themselves with the Biodex System one day before the test.

The participants were seated in the dynamometer chair at 90 degrees of hip flexion with their eyes closed. They were given headphones and were fitted with an GSK-3 air cushion above the leg, which was inflated to a pressure of 40 mmHg to minimize cutaneous sensory information (Callaghan et al., 2002). All participants had the ��hold�� button in one hand so that they could stop the dynamometer��s lever arm with their thumb when they thought it was at the target angle (Willems et al., 2002).

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>